Real-Time Focal Position Correction for CT, Delivering Superior Image Quality, Lower Radiation Exposure, and Reliable Emergency
Imaging Without Tube Preheating
Gantry | |
Aperture | 700mm土10mm |
Scan FOV | Optional 400/450/500 mm |
Field of View Extension | Corresponding600/650/700 mm |
Mechanical tilt capability | ±30° |
Tilt positioning accuracy | ±0.5° |
SDD | 950±2mm |
SID | 570±2mm |
Rotation mode | Clockwise |
Gantry type | Low voltage |
Shortest rotation time | 0.75s/360° |
Orientation system | 3D laser orientation |
Safety protection | Tilt interference by software and hardware |
Temperature detection | Provide temperature detection interface to prevent hot air hazards |
Tube | |
Tube anode heat capacity | 3.5MHU |
Continuous anode input power | >34kW@LFS/28kW@SFS |
Heat dissipation rate | >8.0kW(735 kHU/min) |
Tube focus | Small focus 0.7mm*0.8mm Large focus 1.2mm*1.4mm |
High voltage generator | |
Continuous output of HV generator | 34kW |
Tube kV selections | 60kV、70kV、80kV、100kV、120kV、140kV |
Tube mA range | 10mA~350mA |
Maximum continuous scan duration | ≥100sec |
Detector | |
Detector type | Solid-state GOS ceramic |
Detector Z-axle arrangement | 24 non equidistant rows, effectively reduce signal loss |
Width of Z-axle detector | 19.2mm@lS0 center |
Detector columns of channels per row | 624/720/816 |
Numbers of detector columns | 14976/17280/19584 |
Minimum slice thickness of scan | 0.6mm |
Acquisition mode | 16x0.6mm, 16x1.2mm |
Table | |
Maximum patient weight | 200kg |
Maximum vertical-movable range | 400mm |
Maximum horizontal-movable range | 1600mm |
Table horizontal-position repeatability | 0.25mm |
Table horizontal-scannable range | 1500mm |
Couch width | ≥420mm |
Repeat positioning accuracy | ≤ 1 mm |
Speed of horizontal Movement | 2.4 mm/s- 100 mm/s,±10% |
Time of vertical Movement | 25s |
Foot pedal of patient table control | Provided |
System Performance | |
Console computer | Support configurable plan |
Monitor | Support configurable plan |
Operating system | Windows11 |
DICOM Conformance Standards | DICOM 3.0 |
Image burner | DVD |
DICOM 3.0 interface | Support HIS and PACS |
Scan&Recon | |
Scout mode | PAT, LAT, DUAL |
Maximum scout length | 1500mm |
Maximum scan time of helical | 100s |
Maximum scan length of helical | 1500mm |
Range of pitch | 0.25-1.75(continuous parameter) |
Image reconstruction matrix | 512x512, 1024x1024 |
Speed of image reconstruction | MAX 16 Image/second |
Image noise | ≤0.35%@Center dose ≤40mGy |
CT uniformity | ±4HU |
CT accuracy | Air:-1000±10HU;water:0±4HU |
Low contrast resolution | 4.0mm @0.3% |