The 6.5 Inches 3 and 5 Lead Truncated Exponential Monophasic AED Defibrillator First Aid Portable Monitor Machine is a highly effective and versatile training tool designed to simulate real-life cardiac arrest situations. Its combination of ECG monitoring, shockable rhythm simulation, and voice and visual prompts makes it an invaluable resource for both beginners and healthcare professionals. Whether used in clinical environments, first-aid courses, or EMS training, it helps ensure that users are well-prepared to respond to life-threatening cardiac emergencies with confidence and competence.
6.5 Inches 3 and 5 Lead Truncated Exponential Monophasic AED Defibrillator
The 6.5 Inches 3 and 5 Lead Truncated Exponential Monophasic AED Defibrillator First Aid Portable Monitor Machine is a comprehensive training and monitoring device that simulates the operation of a monophasic AED (Automated External Defibrillator) used in emergency situations.
This device provides a realistic simulation of defibrillation scenarios, while also enabling users to monitor vital signs through ECG (electrocardiogram) monitoring. It is equipped with a 6.5-inch display and supports 3-lead and 5-lead ECG configurations, which makes it suitable for both basic and advanced training.
Product Specifications
Weight | 10 pounds (4.95 kg) (basic configuration) |
Size | 13 x 12.5 x 5.3 inches (33 x 31.8 x 13.5 cm) |
Temperature | 0 to 45° C |
Humidity* (NC) | 15 to 95% RH (30 to 90% with CO2 probe) |
Altitude | Up to 4572 M (15,000 feet) |
Temperature | -30 to 70°C (-20 to 70°C with CO2 probe) |
Humidity | 15 to 95% RH (non-condensing) |
Atmospheric pressure | 860 to 1060 hPa |
Recharge Rate | 80% in 7.5 hours. 100% in 9.5 hours |
Product description
Input: 3-lead, 5-lead, patient cable, paddles, or multi-purpose hands-free adapter.
Size: 6.5 inches (16.5 cm) diagonal, non-fade.
Type: color (TFT)
Display Resolution: 800 x 600 pixels.
Sweep Speed: 12.5mm/s,25mm/s,50mm/s
Lead Selections: Paddles (Pads), I, II, III, AVR, AVL, AVF, V.
Frequency Response: (User-selectable).
2 to 20 Hz Limited mode; 1 to 40 Hz Monitor mode (before Rev. T8/U8); 0.05 to 150 Hz Diagnostic mode; 0.5 to 30 Hz AED mode
Common Mode Rejection:
Meets AAMI EC13-1992, section 3.1.2.1c for 1.2 mV; T-wave (1.0 mV with diagnostic response) and 1mV QRS.
Standard Capacity:
Up to 2 hours ECG monitoring or 60 full-energy discharges or 1.5 hours combined ECG, SpO2 and BP monitoring while pacing. Actual operating times will depend on the number of
features activated and the duration of their use. Proper battery are is required to maintain maximum available capacity.
Type: High-resolution thermal array.
Annotation: Time, date, ECG lead, ECG gain, heart rate, defibrillation and treatment summary ACLS events.
Paper Width: 50 mm.
Paper Speed: 25 mm/sec, 50 mm/sec, 12 Lead, 50 mm/sec
Delay: 6 seconds.
Frequency Response: Automatically set to monitor's frequency response.
Treatment Summary: 7 switches to record key ACLS events (IV, INTUB, EPI, LIDO, ATROP, etc.). Automatically logs into memory the type of event, time and ECG sample.
Tx Summary Log: 28 ECG events or 300 non-ECG events.
Record Modes: Manual and automatic (User-configurable).
Heart Rate, BP, SpO2, Resp & Temp Alarm:
Audible:
5 pulse, 800 tone, with a PW of 150 msec,
a PRI of 225 msec, and a repetition interval of 10 seconds.
Visual: Heart Rate Alarm causes the displayed heart rate to flash at 2 Hz.
This display is located at the top of the display and is 0.4" high and 0.28 to 0.840" wide depending on number of digits in the heart rate.
Color is amber, black, white, or whatever the color the display text is.